Customization: | Available |
---|---|
Max Diameter of Workpiece: | <500mm |
Mass Scope of Workpiece: | <900kg |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Computer Controlling System Rotorless Rubber TestingRheometer
CHAPTER 1: Introduction
1.1 The Software Interface
The software interface is consists of five parts (Shown above)
1) The menu panel
Include of File(new data,save data ,load data ),Control(start test ,stop test ,start heat, stop heat,start motor ,stop motor ,multicurve, torque clear, delete data ),Setting(input ,refercurve ,curvecolor ,aotorun, standard, system ),Report and About.
2) The data panel
Display the practice data (torque, time, heat, connections), As well as unit conversion.
3) The curve panel
Display real-time display to read the curve and test curve.
4) The action panel
Shortcut keys, set the test number, material number, test time, test temperature, curvilinear coordinates, curves, color (including test number, material number, test time, test temperature, the curvilinear coordinates the Enter key to enter the settings to save the settings.
Main Parameters:
Model | DZ-321 Moving Die Rheometer |
Standard | GB/T16584 IS06502 |
Temperature | room temperature to 200 Centigrade |
Heating-up | 15 Centigrade/min |
Temperature fluctuation | ≤ ±0.3 Centigrade |
Temperature resolution | 0.1 Centigrade |
Torque range | 0-5N.M,0-10N.M,0-20N.M |
Torque resolution | 0.001NM |
Power | 50HZ, ~220V±10% |
Pressure | 0.4Mpa |
Air-pressure requirment | 0.5Mpa--0.65MPa (user prepare the dia 8 trachea) |
Environment temperature | 10 Centigrade--20 Centigrade |
Humidity range | 55--75%RH |
Compressed air | 0.35-0.40Mpa |
Swing frequency | 100r/min (about 1.67HZ) |
Swing angle | ±0.5 Centigrade ,±1 Centigrade , ±3 Centigrade |
Printing | date, time, temperature,vulcanization curve,temperature curve, ML,MH,ts1,ts2,t10 ,t50, Vc1, Vc2 |
5) The results panel
1.2 Technical
Torque resolution :1/50000;
Torque precision :0.3%;
Torque unit :N.m,N.inch,kg.m,kg.cm,kg.inch,Lb.m,Lb.inch;
Temperature control range :60°C - 300°C;
Temperature fluctuation range :±0.15°C;
Temperature resolution :0.01°C;
After clamping the temperature recovery time :< 1min;
Temperature unit :C ,F;
Acquisition rate:200 SPS;
Language :English ,Simplified Chinese ,Traditional Chinese;
Use standard :GB/T 16584,ASTM D5289,ISO 6502;
Counting parameter :ts1,ts2,t10,t30,t50,t70,t90,Vc1,Vc2;
Software interface :USB2.0;