Lab Rubber No Rotor Moving Die Rheometer

Product Details
Customization: Available
After-sales Service: Engineers Available to Service Machinery Overseas
Warranty: 3 Years
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
1000000 USD
Type of Ownership
Limited Company
  • Lab Rubber No Rotor Moving Die Rheometer
  • Lab Rubber No Rotor Moving Die Rheometer
  • Lab Rubber No Rotor Moving Die Rheometer
  • Lab Rubber No Rotor Moving Die Rheometer
  • Lab Rubber No Rotor Moving Die Rheometer
  • Lab Rubber No Rotor Moving Die Rheometer
Find Similar Products

Basic Info.

Model NO.
RT-101
Max Diameter of Workpiece
<500mm
Mass Scope of Workpiece
<900kg
Type
Material Testing Machine
Maxcapacity
<1000KN
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Oil Cylinder Position
Under
Standards
GB/T16584 ,Is06502
Temperature
Room Temperature to 200 Centigrade
Torque Range
0-5n.M,0-10n.M,0-20n.M
Heating-up
15 Centigrade/Min
Temperature Resolution
0.1 Centigrade
Temperature Fluctuation
≤ ±0.3 Centigrade
Air-Pressure Requirment
0.5MPa--0.65MPa (User Prepare The Dia 8 Trachea)
Swing Frequency
100r/Min
Transport Package
Packed as Export Safety Wooden Case
Specification
OEM, ODM, OBM
Trademark
Evertech
Origin
Qingdao, China
HS Code
90248000
Production Capacity
300 Set/Sets Per Month

Product Description

Product Description
Lab Rubber No Rotor Moving Die Rheometer

RT-101 Rotorless Rheometer is a widely used tester in rubber processing industry, rubber quality control and basic research rubber. For optimize formula of rubber provide accurate data, It can accurately measure the scorch time, rheometer time, sulfide index, the maximum and minimum torque and other parameters.
Specification
 
Product Name
Rotorless Rheometer For Rubber
Standard
GB/T16584/ IS06502 /ASTM D5289
Temperature
room temperature to 200 Centigrade
Heating-up
15 Centigrade/min
Temperature Fluctuation
≤ ±0.3 Centigrade
Temperature Resolution
0.1 Centigrade
Torque Range
0-5N.M,0-10N.M,0-20N.M
Torque Resolution
0.001NM
Power
50HZ, ~220V±10%
 
Pressure
About 0.4Mpa
Air-pressure requirement
0.5Mpa--0.65MPa (user prepare the dia 8 trachea)
Environment temperature
10 Centigrade--20 Centigrade
Humidity range
55--75%RH
Compressed air
0.35-0.40Mpa
Swing frequency
100r/min(about 1.67HZ)
Swing angle
±0.5 Centigrade ,±1 Centigrade ,±3 Centigrade
Printing
Date,time,temperature,vulcanization curve,temperature
curve,ML,MH,ts1,ts2,t10,t50,Vc1,Vc2.
Lab Rubber No Rotor Moving Die RheometerLab Rubber No Rotor Moving Die RheometerLab Rubber No Rotor Moving Die RheometerLab Rubber No Rotor Moving Die RheometerLab Rubber No Rotor Moving Die Rheometer

Main Functions:

 
RT-101 Rotorless Rheometer for Rubber used monolithic rotor control, which include: host, temperature measurement, temperature control, data acquisition and processing, sensors and electrical chains and other components.
These measurements, temperature control circuit consists of a temperature control device, platinum resistance, heater composition, capable of automatic tracking power and ambient temperature changes, automatically correct PID parameters to achieve fast and accurate temperature control purposes.
Data acquisition system and mechanical linkage to complete the rubber vulcanization process of force torch signal automatic detection, automatic real-time display of temperature and settings.
After curing, automatic processing, automatic calculation, print vulcanization curve and process parameters.
Show curing time, curing power Ju, also has a variety of audible alert.

RT-101 Rotorless Rheometer for Rubber controlled by computer, the computer setting the parameters of the direct control of test parameters rheometer.
Display real-vulcanization curve and temperature curve, store test results, different adjustable comparison of test results and in a different color.
Lab Rubber No Rotor Moving Die Rheometer
How It Works:
The rubber sample into the mold cavity is almost entirely enclosed and maintained at test temperature, the mold cavity are of two parts, of which the lower part with a small linear reciprocating movement (swing oscillation), oscillatory shear specimen produced strain determination is the reaction torque of the mold cavity (force), this torque (force) depends on the shear modulus of rubber.
Curing test specimens after the start of the shear modulus increases, the computer machine real-time display and record the torque (force), when the torque (force) rose to a stable value or the maximum as well as return to the state, they get a torque ( force) and time curve, that is, curing curve (Figure 1), shape of the curve and test the temperature and plastic material characteristics.
Our Advantages
Lab Rubber No Rotor Moving Die Rheometer

Features:

 
1. This instrument is really confined mold cavity, and the United States Alpha (formerly Monsanto) has done. Repeatability, and test data comparable with the Alpha. At the international leading position in the same industry. 2. The instrument development platform based on large databases, temperature control devices using the software to directly control and collection and processing. Instrument to overcome the general curing temperature of the shortcomings of using temperature controller (accuracy poor). The technical leadership of international new trend. 3. This instrument has statistics, analysis, storage and comparison functions. Humanized design, easy to operate. 4. Using imported high-precision sensors.
Recommend Products
Lab Rubber No Rotor Moving Die RheometerPacking & Delivery
Lab Rubber No Rotor Moving Die RheometerLab Rubber No Rotor Moving Die Rheometer
Shippment:
-By sea
-By plane
-By couriers, TNT, DHL, FEDEX, UPS, etc.
 
Standard Export carton:
1.Inner Package: Thin plastic film surround the machine;
2.Outer Package: Internationally standard package export safety wooden case.

Company Profie
Lab Rubber No Rotor Moving Die Rheometer
FAQ
Q1: How long is the delivery time?
A:Normally 5-10 working days after received deposit,we have our own factory,the delivery time can be adjust flexible.

Q2: What is the warranty for the equipment?
A: One year. We can provide you lifelong technical support.

Q3: What is the payment terms?
A: T/T, L/C, Western Union, etc

Q4: How about the products quality?
A: Our products apply to ISO, ASTM, GB, etc

Q5: Is it OK to print my logo on machine product?
A: Yes. Please inform us formally before our production and confirm the design firstly based on our sample.

Q6. What is your terms of payment?
A: T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and packages before you pay the balance.
or 100% L/C at sight .

Q7: Can we test sample before place order?
A: Of course,we can test sample and provide test report to you with free.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier