Item |
Design parameter |
Effective diameter | 500-4500mm |
Effective length | 1000-20000mm |
Working temperature | 100-450ºC |
Working pressure | 0.5-5.0Mpa |
Raising pressure speed | 0.1Mpa/min continuous adjustment |
Perssure error | ±0.01Mpa |
Raising temperature speed | 0.5-7 ºC/min continuous adjustment |
Temperature go down speed | 0.5-7 ºC/min continuous adjustment |
Cooling ways | Water cool and wind cool |
Point temperature error | ±1.2 ºC |
Control temperature and test temperature point |
2-20 points |
Vacuum degree of cavity | -0.098Mpa (absolutely pressure ) |
Extra vacuum pipe |
Extract 2-20 pipe extract and test is independent |
Test vacuum pipe |
Test 2-20 pipe extract and test is independent |
Continuous working ability | ≥ 50 hours |
• Welding method: Automatic submerged arc welding, it has advantages of high productivity, good weld quality and low labor intensity. And it also hasn't arc radiation.
• Our company has own special flaw detection to ensure the quality of products.
• The ways to open the door: Open door manually, open the door by electricity, open the door by hydraulic.
• The sealing way: With the gas-filled silica gel seal ring, the sealing effect of the equipment is significantly better than others'. And the life of the equipment is more than one year.
• Safety interlocking methods of the door of the tank: Automatic pressure safety interlocking method and Manual safety interlocking method, it solved the safety problem of wrong operation.
FAQ
1. What is max diameter we can do for you?
The maximum diameter which our company can make is 4.5m. And the length is up to your requirements.
2. How much capacity can you treat per tank at a time?
It is up to the diameter and length of the equipment designed by your demands.
3. Is the control system manual, semi-automatic or full-automatic?
Our basic control system is full-automatic operation system.
4. Can we install the equipment by ourselves?
Of course, we will provide you with detailed installation information.