Siemens PLC Automotive Radiator Rubber Hose Lining Roller Vulcanization Steam Autoclave
For steam direct heating vulcanization autoclave, the temperature, pressure and vulcanization time are controlled automatically. Specialty thermal conductive heat sink have good heat dissipation performace and long service life. The steam enter through two automatic angle seat valves from back of tank, and the diffusion tubes of thermal conductive heat sink are uniformly arranged in the tank. The hot air in thewind shield is pushed to the tank door through draught fan and then turn back. Hot air circulate continuously from front to back of the tank and distribute heat uniformly. And the temperature is even and no dead angle in the tank, the pressure is constant. Thus it can prevent the different quality of the product because of the uneven temperature and pressure.
After set working procedures, the heating, heat preservation, vulcanization, etc. can be finished by automatic control system. When vulcanization finished, the equipment will give alarm.
Horizontal autoclave is mainly used for vulcanizing non-modeled rubber products, such as rubber shoes, rubber hose, cable, rubber roller, tape, etc., sometimes, is also used for vulcanizing modeled rubber products
Classification of Autoclave:
1)According to control method:
full automatic type and semi automatic type
2)According to heating method:
l Steam direct heating autoclave;
l Steam indirect heating autoclave;
l Dry heating autoclave;
l Electric heating hot water autoclave.
)According to open-door method:
l Manual quick open the door;
l Electric motor door;
l Hydraulically automatic open the door.
Technical Parameter:
TYPE |
HEATING METHOD |
MODEL |
CONTROL |
DIAMETER (mm) |
LENGTH (mm) |
MEDIUM |
DESIGN PRESSURE (Mpa) |
TEMPERATURE (°C) |
DIRECT |
ELECTRICAL |
AE0102.D |
AUTOMATIC |
1000 |
2,000 |
PRESSURE AIR |
0.35 |
120C~310C |
AE0204.D |
2000 |
4,000 |
0.35 |
120C~310C |
||||
AE0206.D |
2000 |
6,000 |
0.35 |
120C~310C |
||||
SE0304.D |
SEMI-AUTOMATIC |
3000 |
4,000 |
0.35 |
120C~310C |
|||
INDIRECT |
STEAM |
SE0410.I |
4000 |
10,000 |
0.35 |
120C~310C |
||
SE0509.I |
5000 |
9,000 |
0.35 |
120C~310C |
Those autoclave in the chart are standard configurations.
We also can customize autoclave according to your specific requirements or your drawing.
Features:
1)Door Sealing Method:
Using inflatable silicone ring, the sealing effect is better than other way. The service life of sealing ring is more than one year.