Lightweight Vulcanizer for Belt Splicing with PVC

Warranty: 2 Years
Control Type: CNC
Automatic Grade: Automatic
Power Source: Electric
Type: PVC Conveyor Belt Welding Machine
Power(Kw): 16kw
Customization:

Contact Supplier

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
FC300/600/900/1500 for belt
Dimension(L*W*H)
1370X370X310mm
Weight
55kgs 65lbs
Certification
Ce
After-Sales Service Provided
Engineers Available to Service
Material
Aluminum Alloy
Splicing Time
12mins
Effective Length
2360mm
Transport Package
Packed in Wooden Case
Specification
red
Trademark
Evertech
Origin
Shandong, China (Mainland)
HS Code
84778000
Production Capacity
100 Set/Sets Per Month

Product Description

Tool Specification and Parameter

Tool Specifications FC-300 FC-600 FC-900 FC-1200 FC-1500
Effective length 305mm/12'' 610mm/24'' 914mm/36'' 1219mm/48'' 1524mm/60''

Effective width

130mm/5.1'' 130mm/5.1'' 130mm/5.1'' 130mm/5.1'' 130mm/5.1''

Weight lower part

10kg/22lbs 16kg/33lbs 20kg/44 lbs 28.5/56 lbs 32kg/68 lbs

Weight upper part

11kg/24 lbs 13kg/30 lbs 18kg/40 lbs 25.5kg/50 lbs 30kg/65 lbs

Total weight

21kg/46 lbs 30kg/63 lbs 38kg/84 lbs 54kg/106 lbs 62kg/133 lbs

Length

505 mm / 19.9 "

805 mm / 31.7 "

1105 mm / 43.5 "

1405mm/ 55.3"

1705mm/ 67.1"

Overall Height

220 mm / 8.5 "

225 mm / 9 "

225 mm / 9 "

225 mm / 9 "

225 mm / 9 "

Max. pressure

2 Bar / 28 PSI

2 Bar / 28 PSI

2 Bar / 28 PSI

2 Bar / 28 PSI

2 Bar / 28 PSI

Max. temperature

200 ºC / 390 ºF

200 ºC / 390 ºF 200 ºC / 390 ºF 200 ºC / 390 ºF 200 ºC / 390 ºF

Dimensions 

for transport

 (L x W x H)

770 x 370 x 310 mm

(30 x 15 x 12 ")

1012 x 352 x 280 mm

(42  x 15  x 12 ")

1312 x 352 x 280 mm

(54  x 15 x 12 ")

1612 x 352 x 280 mm

(68 x 15 x 12")

1912 x 352 x 280 mm

(76 x 146 x 122")

Weight 

for transport

26 kg / 57 lbs

35 kg / 77 lbs

43 kg / 95 lbs

84KG/180lbs

96KG/210lbs

Price (USD) 9000 10500 12000 13000 14500

 

 Splice Press machine
Safety and Operating Manual

WARNING!

IMPROPER OR UNSAFE use of this splice press can result in damage to the press and/or physical harm. This manual contains important information about product function and safety.  Please read and understand this manual BEFORE operating the press. Please keep this manual available for other users and owners before they use the  press. A copy of the  Press Owner's Manual can be accessed on 

Main Components

Clamp Bar Studs & Thumbnuts (4)

Top Press Beam

Handle

Press Connector Bolts (4)

Clamp Bar (2)

Bottom Press Beam

Start Button (green)

Eurotherm Heat and Time Controller

Umbilical Power Cable Connector

Pressure Controller

Pressure Relief Button (red)

Main Power Cable Connector
Lightweight Vulcanizer for Belt Splicing with PVC
Lightweight Vulcanizer for Belt Splicing with PVC

Introduction to the  Splice Press

The  splice press is an all-in-one solution for splicing thermoplastic conveyor belts (e.g. PVC polyurethane).

No external control box, air pump, or water cooling tank are required.

The  presses are provided with electric heating and built in air cooling. The splice process runs fully automated.

Splice pressure is applied by an internal compressor, max. 2 bar (28 psi)

Heats up to a splice temperature of max. 200°C (392°F)

Keeps it at the splice temperature (adjustable dwell time)

Cools down to the cooling temperature (safe temperature to take the belt out)

For thicker belts a preheat temperature and preheat dwell time can be applied

  The bottom heating can be set lower or higher than the top heating

  The splice surface is 190 mm wide (7.5"); the heated zone is 190 mm wide (5.1")
Lightweight Vulcanizer for Belt Splicing with PVC

If the belt is relatively thick a problem might occur where the outside of the belt is at the splicing temperature too long, waiting for the inside to reach the required temperature. Molten material might flow away or discolor and fabrics might shrink. To avoid this problem from happening, the preheat option can be used. This option heats the belt up (outside and inside) to a temperature just below the melting temperature. After the preheat stage, the inside splice temperature can be reached much quicker, minimizing the risk for unwanted flow of material, discoloring or fabric shrinkage.
Lightweight Vulcanizer for Belt Splicing with PVC

The reading of the display relates to the top temperature of the press. If more or less heat is required at the bottom of the belt, the "bottom heat factor" can be used. Please note that this factor relates to a plus or minus amount of heat (%), not to a specific temperature.

 presses are available in 5 different sizes:

 300 mm effective (12")

  600 mm effective (24")

900 mm effective (36")

1200 mm effective (48")

  1500 mm effective (60")

 presses function on different voltages
Lightweight Vulcanizer for Belt Splicing with PVC

1. presses are supplied with a flight case for both storage purposes and also for easy transport 

     to on-site jobs.  2. Place press in the flight case so the end with the power receptacles is facing the storage              compartment.  This will protect the receptacles from damage when transporting.  3. Flight cases have four wheels. 

 

 4.  Flight cases can be stacked on top of each other, but need to be secured during transportation.

 

General Safety Rules 

 

–Save These Instructions–

 

Signal words:

 

“DANGER” indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.  The signal word is limited to the most extreme situations.

 

“WARNING” indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

 

“CAUTION” indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.  It may also be used to alert against unsafe practices.

 

Safety Symbol

 

This international safety symbol is used to identify and call attention to specific safety matters.

 

Safety Information

 

To Avoid Severe Personal Injury or Property Damage, read carefully and understand the following Safety Precautions.

 

overall safety rules

 

Danger

 

Terminate electrical hazards by removing power cord from wall receptacle or machine base inlet.

 

Danger

 

To Avoid Severe Personal Injury or Property Damage, read carefully and understand the following Safety Precautions.

 

Warning

 

Terminate pressure related hazards by pressing the red pressure relief button.

 

CAUTION

 

Press platens develop over 5 tons of clamping force.  When operating the press keep the four press connector bolts in place by hand tightening.

 

CAUTION

 

Avoid temperature related hazards by handling press components and workpiece after fans shut down.

 

Safe Operation of  Press 

 

Locate a position in facility where appropriate voltage and power receptacles are available to operate the  press. 

 

Warning

 

Operating the press on incorrect voltage can cause serious damage and potential hazards.  The following  power cords are available: 

 

a.230 volt; single phase

 

b230 volt; three phase

 

c.400 volt; three phase + neutral

 

d.  460 volt; three phase

 

Visually inspect power cord:

 

Danger

 

a.Inspect cord for damage.  Do not use power cord in a damaged state.  Either replace cord or have an electrician remove damaged section and reattach plug.  

 

b.Confirm compatibility between plug end and power receptacle.  If incorrect, find alternate power source or have electrician apply correct plug,

 

 

c.DO NOT plug power cord into wall receptacle at this time.  Later in the operation, when ready to connect power follow these safe and proper operating procedures:

 

i.  First, plug power cord into machine base power inlet.

 

ii.  Second, insert plug end into wall receptacle.

 

Important! Only plug power cord into wall receptacle AFTER power cord has been attached to the tool.


Lightweight Vulcanizer for Belt Splicing with PVC
 


 

 

 

 

Send your message to this supplier

*From:
*To:
avatar Mr. Victor Wang
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now